Testing must be in accordance with the 2003 edition of nfpa 1962, standard for the inspection, care, and use of fire hose, couplings, and nozzles and the service testing of. Statement of problem and substantiation for public input. Contractors frequently do not know what edition of a particular nfpa standard the hospital is required to comply with. Fire hose testing standard operating guidelines the purpose of this guideline is to explain the proper procedure for the testing of fire service hose. Aggressive fire safety is committed to providing quality and.

Supply fire hose shall be service tested to a minimum of 200 psi. Standard for the care, use, inspection, service testing, and replacement of fire hose, couplings, nozzles, and fire hose appliances, which is for fire hose operators. Portalsvfisfireandemsoperationsfirehosetestingvfis. Publishers publisher directory free standards standards management. Standard for the care, use, inspection, service testing, and replacement of fire hose, couplings, nozzles, and fire hose appliances update to the 20 nfpa 1962 to be sure fire hose, nozzles, and fire hose appliances can operate properly for effective fire suppression. Testing fire hose is dangerous enough without intentionally adding to the risk. Conduct an acceptance test on each section of fire hose before it is placed in the hose inventory. Service requirements fire protection equipment requires. Fire hose practices international fire service training. Fire hose testing a challenge for many fire departments, especially volunteer departments, is finding personnel to assist with annual fire hose testing. Attack fire hose shall be service tested to a minimum of 300 psi. Nfpa 1962 compliant fire hose testing fire suppression. Updated to address advancements in technology, nfpa 1962. Replacement if appliance fails any, it shall be removed and repaired or replaced.

Standard on fire hose presents the minimum requirements for the design and construction of new fire hose, the testing required to verify the design and construction, and the inspection and testing required of all new fire hose. Nfpa generator testing nfpa 110 nfpa hose testing nfpa 1962 nfpa ladder testing nfpa 1932 nfpa pump testing nfpa 1911 nfpa waterbased fire protection systems and many more. This standard provides requirements for fire hose, couplings, nozzles, and appliances in order to ensure a reasonable level of reliability when they are used at an incident. Apparatus from nfpa 1962, care, use and services testing of fire hose. Today, while others are still using stopwatches, needle gauges and handstenciling numbers on hoses, trained firecatt technicians are in mobile test labs using the only computerized, automated and objective hose testing technology in the nation, along with a unique barcoding system to track and document performance. The test shall comply with the provisions of nfpa 1962, standard for the care, use, and service testing of fire hose including couplings and nozzles. Standard for the inspection, care, and use of fire hose, couplings and nozzles. Fire hose testing on site keeping your fire hose in service with the limited time of todays fire departments our service allows you to free up firefighting personnel for more important duties. Hose should be tested when purchased new according to the manufacturers recommendations and using this procedure. Mukwonago fire department operating procedures proper procedures for conducting service testing of fire hose.

Fire hose nfpa 1962 2008 edition hydrostatic test 14. Standard for the inspection, care and use of fire hose, couplings and nozzles and the service testing of fire hose 2008. This nfpa hose testing ensures that your fire hoses, couplings, and nozzles are all ready for use in the case of an emergency. This procedure outlines the national fire protection associations nfpa standards 1962, standard for the care, use and service testing of. The new standard increases the pressure to 3psi for attack line and leaves. Nfpa 1963 contributes to a set of standards that provide manufacturers with consistent requirements for the whole fire hose system. Nfpa is committed to serving the publics increasing interest in technical information, and.

Im always pleased when first due services is done completing the baldwinsville fire department hose testing because i know it was done right the hose that needs repairs is marked properly and set aside for us. Copies of this document can be obtained from nfpa by calling. Fire hose, couplings, firefighting nozzles and fire hose appliances. While competitors are still manually turning dials and reading gauges, trained firecatt technicians are in stateoftheart mobile test labs using the only computerized, automated and objective hose testing technology in the nation. For example, the latest edition of inspection and testing of sprinkler systems is the 2014 edition. This document complements nfpa 1962, standard for the care, use, inspection, service testing, and replacement of fire hose, couplings, nozzles, and fire hose appliances, which is for fire hose operators.

First due services llc ladder testing fire hose testing. Ifsta 6th edition chapter 15 fire hose firefighter ii. The purpose of this guideline is to explain the proper procedure for the testing of fire service hose. Standard for the care, use, inspection, service testing, and replacement of fire hose, couplings, nozzles, and fire hose appliances contains the latest criteria for. National fire protection association nfpa 1962, standard for the care, use, inspection, service testing and replacement of fire hose, couplings, nozzles and fire hose appliances 20 ed. Pdf shall be tested to the pressure marked on the hose jacket.

Nfpa 1962 standard for inspection, care, and use of fire hose, couplings, and. Origin and development of nfpa 1962 nfpa originally developed a recommended practice for the care, maintenance, and use of fire hose in 1936 through its committee on field practices. Hose testing shall be completed annually and in conjunction with the guidelines set. Fire hose should be tested as set forth in nfpa pamphlet 1962, standard for the care, use, and service testing of fire hose including couplings and nozzles, latest edition.

Standard for the inspection, testing, and maintenance of. This procedure outlines the national fire protection associations nfpa standards 1962, standard for the care, use and service testing of fire hose including couplings and nozzles. Emergency operations requiring water would, by necessity, be limited to those locations immediately adjacent to a. They put neater hose lays in then my veteran firefighters do. After 1987, all hose should have a pressure labeled somewhere on the hose. Standard on the care, use, inspection, service testing and replacement of. From nfpa 1962, care, use and services testing of fire hose including couplings and nozzles. Patented, proven and fire chief approved, firecatts advanced technology has revolutionized fire equipment testing. We then provide you with complete documentation of test records. Standard for the care, use, inspection, service testing. Fire hose practices by tom ruane it might be said that. Update to the 20 nfpa 1961 to maximize equipment performance. This standard covers the care, use, inspection, service testing, and replacement of fire hose, fire hose couplings, firefighting nozzles, and fire hose appliances, and the associated record keeping.

Nfpa 1962 firehouse forums firefighting discussion. Nfpa 1962, 20 edition nfpa 1962 update cottrell associates, inc. It is also important that all the air in the hose be removed. Nfpa 1962 ch 4 care, use, inspection, service testing, and. Remove pre1987 lengths from service by mark conroy.

As part of its commitment to enhancing public safety, nfpa makes its codes and standards available online to the public for free. If your hose says service test 400psi then you service test it to 400psi. Standard for the inspection, testing, and maintenance of waterbased fire protection systems 2017 edition reference. Testing fire hose under pressure is a dangerous task and safety precautions should be followed. Hose testing firehouse forums firefighting discussion. Fireone is in the business of service testing fire department pumpers, fire hose, nozzles, ground ladders and aerial ladders. In nfpa 1962 there is no defined measurement and therefore no consistency for slippage failure. This edition of nfpa 1962 was approved as an american national standard on january 17, 2003. Standard for the care, use, inspection, service testing, and replacement of fire hose, couplings, nozzles, and fire hose appliances nfpa educational messages desk reference 20 edition. Standard for the inspection, care and use of fire hose, couplings and nozzles and the service testing of fire hose 2008 nfpa on. We thoroughly test all fire hoses with stateoftheart equipment which eliminates the use of your pumps while maintaining proper safety protocols.

The process can be sometimes confusing, but the experts at fire protection group, inc. The impact of nfpa 1962 on fire department hose testing. Standard for the care, use, inspection, service testing, and replacement of fire hose, couplings, nozzles, and fire hose appliances. This task is manpower intensive and although it seems to be fairly simple there are many intricacies to the nfpa 1962 standard that can easily be overlooked. At first due services, llc, we offer quality services to ensure the safety and efficiency of all your needs as per the nfpa 1962 standards. After all, george saadian, founder and president of fire protection group, inc. System tests each preconnected line or any attack line used for interior firefighting operations on a fire apparatus, together with the nozzle or hose connected appliance it. Fire departments buy their hose according to nfpa 1961, standard on fire hose, and they test, maintain, or replace it based on nfpa 1962, standard for the care, use, inspection, service testing, and replacement of fire hose, couplings, nozzles, and fire hose appliances. Each fire hose appliance shall be assigned to an identification number for use in recording its history throughout its service life. Start studying ifsta 6th edition chapter 15 fire hose firefighter ii.

Hose 5 years3 years nfpa 1962 hose connections annually 6. Also, appliance users and the authority having jurisdiction shall establish a replacement schedule for their appliance that takes into consideration the use and age of the appliance and testing results. National fire protection association, 1 batterymarch park, p. This standard provides requirements for fire hose, couplings, nozzles, and. Learn vocabulary, terms, and more with flashcards, games, and other study tools. Apply nfpa 1962 to help ensure fire hose, nozzles, and fire hose appliances prove effective in fire suppression operations. How important is maintenance and testing of ground ladders and fire. Nfpa 1932 standard on use, maintenance, and service testing of inservice fire department. A record of each fire hose appliance shall be maintained from the time the appliance is purchased until it is discarded. The purpose of hose testing is to ensure that the hose is being maintained in optimum condition. Online access to nfpa s consensus documents conveniently places important safety information on the desktops of traditional users as well as others who have a keen interest. The procedure fire hose should be tested as set forth in nfpa pamphlet 1962, standard for the care, use, and service testing of fire hose including couplings and nozzles, latest edition.